RSB6 Digital Kits: Buy Now

With the RSB6 Pancake Load Cell Digital Kits, you can connect the load cell to your PC or tablet through a USB connection using our digital interfaces — DI-100U or DI-1000U. Each load cell is individually paired and calibrated with its digital interface to ensure accurate and reliable measurements. Calibration can be performed in Compression mode, Tension mode, or Universal mode (supports both compression and tension applications).

Once calibrated, the load cell and interface must be used together as a matched pair. When connected to a PC or tablet, the system appears as a virtual COM port, enabling easy communication with terminal emulators, custom software, MATLAB, LabVIEW, and other data acquisition applications. We highly recommend using our LoadVUE Pro, SensorVUE, or ControlVUE software to easily and accurately view, log, and plot sensor data.RSB6 pancake load cell digital kit to connect to a PC or Tablet

To build your order, select the Capacity of load cell, Digital Interface, Calibration type, any Accessories, and Expedited Processing option (if required). 

NOTE: Each load cell needs to be calibrated with its own interface and the pair needs to be calibrated together. 

RSB6 Pancake Through-Hole Load Cell: Digital Kits

Please select a load cell and then add an interface, calibration and software from the choices shown below. Please note that the load cells come uncalibrated with a nominal mV/V value. If you do not need an interface but want calibration for the load cell please add the ACAL-MV*C0x calibration service to get a specific mV/V value.

$

Digital Interfaces with USB/UART Output

Select an interface to mate with the load cell you selected & add a calibration service for each load cell. The DI-1000U and DI-400U come with a miniB to USB A Output cable each. The DI-100U offers UART output by default and comes with a miniB to miniB output cable and an S2U Serial to USB Dongle. Add HX-100 adapter board for easy access to UART output. The max data rates and number of channels is shown for each item. If you need higher speeds see options in the next selection box.

$

Calibration - Digital (with DI-100, DI-400, DI-1000 family)

When connecting a load cell with an analog interface, add ACAL*C0x. When connecting with a digital interface add DCAL*C0x. If no interface is needed but you want analog calibration of the load cell then select ACAL-MV*C0x for a mV/V value specific to your load cell. For capacities over 10K lbs add ACAL-HC*C0x or DCAL-HC*C0x.

$

Software (for use with Digital Interfaces)

We highly recommend that you buy a copy of LoadVUE Pro if using one digital load cell at a time or SensorVUE if buying and using multiple load cells simultaneously. These two specific applications run on Win 8/10/11 and offer calibration utilities, easy access to remote support and allow you to display, log and plot data without any coding! Use LoadVUE Lite to Display data only; LoadVUE Pro to Display, Log, and Plot data from one sensor at a time; SensorVUE to Display, Log, and Plot data from multiple sensors simultaneously; ControlVUE to Display, Log, and Plot data and Control devices. If you wish, you could write your own code using any language such as Python or LabVIEW. All our digital interfaces come with built in ASCII command sets similar to AT commands.

$

Electronic Accessories

Add an electronic accessory from the options shown below if needed. DI-100U and iLoad Series interfaces come with an S2U. All wireless interfaces come with a power supply with US style adapters. The most commonly selected accessory is the UX-100 extender cable to add 5m or 15 feet to the distance from the USB output to your PC/Tablet.

$

Mechanical Accessories

Sometimes adding one of these mechanical accessories to your order can help expedite your timeline because of the convenience of having a finished product. Choose one of these accessories that might make things easier for you.

$

Display (compatible with Digital Interfaces)

Use the DS-3000-Pro touch screen display with any USB load cell kit, i.e. load cell + interface. The load cell and interface pair must be calibrated before it is connected to the display. Use DS-3000-Pro-1 with single load cell kit and DS-3000-Pro-4 with up to 4 load cell kits. This display does not work with analog kits that use AI-1000 or AI-1000-CV. The touch-screen displays allow you to show values (numeric) from our digital load cells or resistive load cells connected to a digital interface. They work with a calibrated system (load cell + interface pair). You do NOT need a PC or software if you choose to use to display on one of these devices. It comes with a power supply with a US style two prong adapter.

$

Expedited Processing

Our normal processing for orders received with payment or with POs for those with established accounts is about two weeks. For faster processing select one of the options shown below. This expedited processing is on a best efforts basis.

$